Redox/ORP Probe
Types: RX6-1AU - RX6-2AU
Excellent measurement precision unaffected
by any interference caused by flow fluctuations for enhanced process control
Single junction reference
system with high-sensitivity for fast measurement interaction and minimal calibration and servicing
Screened waterproof low-noise coaxial cable permanently fixed to head of electrode with quick release BNC connector
Technical Details
Measurement Range :- ± 2000 mV - Temperature :- 60°C - Pressure :- 6
Bar - Diameter : - Ψ 12mm
Sensing Electrode :- Gold - Diaphragm :- Pellon
PTFE - Electrolyte :- KCL Gel - Length :- 122mm
Redox Sensor :- RX6-1AU (Polycarbonate Body) -
Redox Sensor :- RX6-2AU (Epoxy Body)
Applications
| Cyanide Destruction | Ozone
Monitoring | Cooling Towers | Aquaculture | Pulp & Paper Bleaching |
Redox Probes
ORP Sensors
High-Performance ORP Sensors
Comprehensive range of versatile Single and Double Junction Redox (ORP) Probes and Sensors provide
superior process control and thrive in diverse chemical environments offering the perfect balance of precision and measurement sensitivity on
oxidation-reduction potential levels, redox sensors measure the cleanliness of water and its ability to break down contaminants
therefore the environment you drop them into matters immensely for the safety, efficiency and control of the system.
Dependent
on the intended application electrodes are manufactured in various shaft materials: - Glass Electrodes - Polycarbonate
Electrodes - Epoxy Electrodes
The Right Junction for Every Application
Single Junction Probes: The cornerstone of electrochemical
analysis and economical choice for general-purpose applications designed to measure the oxidizing or reducing power of an aqueous
solution particularly favoured for their economical design and rapid response in harsh environments where
contaminants are low and applications where rapid fluctuations must be caught in real-time
Double
Junction Probes: Engineered specifically for challenging environments the secondary internal junction adds an extra physical barrier
to prevent the reference element from contamination
of substances that contain heavy
metals, sulfides and proteins significantly reducing the frequency of sensor replacement and minimising calibration drift.
Choosing the Right ORP Sensing Probe
Redox probes operate using a two-part electrochemical measurement system choosing
the right sensing electrodes largely depends on the chemical environment with Platinum generally seen as the industry
standard due to it's excellent chemical resistance and versatility in numerous water treatment processes, whilst Golds
unique electrochemical properties make it highly resistant to "poisoning" in presence of specific ions ensuring stable and repeatable
measurements in specialized industrial processes.
Redox Probe
Type RX6-SJ
Key Features
Exceptional precision with minimal interference
caused by flow fluctuations with optimum performance process control
Single junction reference system
with high-sensitivity for fast electrolyte interaction with minimal calibration and servicing
Probes
has permanently fixed waterproof six meter coaxial cable with industry standard quick release BNC connector
Technical Details
Measurement Range :- ± 1000 mV - Temperature :- 60°C - Pressure
:- 6 Bar - Diameter : - Ψ 12mm
Sensing Electrode :- Platinum - Diaphragm :- Pellon
PTFE - Electrolyte :- KCL Gel - Length :- 122mm
Applications
| General Laboratory | Swimming
Pools | Water Monitoring | Domestic Pools | Water Treatment |
Single Junction Redox (ORP) Probes
Double Junction Redox (ORP) Sensors
Type: RX6-DJ
Key Features
Real-time monitoring for rapid-response
intervention for superior electrochemical stability and consistent performance
Dual junction
isolation system acts as a barrier preventing reference contamination and poisoning from harsh chemicals
Screened low-noise coaxial cable with high insulation resistance & low capacitance properties for fast
response times
Technical Details
Measurement Range :- ± 1000 mV - Temperature
:- 60°C - Pressure :- 6 Bar - Diameter : - Ψ 12mm
Sensing Electrode :- Platinum
- Diaphragm :- Pellon PTFE - Electrolyte :- KCL Gel - Length :- 122mm
Applications
| Cooling Towers | Swimming Pools | Wastewater | Aquaculture | Clean-In-Place (CIP Systems |
Redox/ORP Sensor
Type: RX3-WW-DJ
Key Features
Platinum sensing electrode design provides
a large surface area for highly responsive and stable redox measurements
Specially formulated glass body
for operations up to 80°C temperatures the ideal choice for volatile industrial cycles
Detachable S8
cable connection with screwed PG13.5 configuration to head of electrode with BNC type connector
Technical Details
Measurement Range :- ± 1000 mV - Temperature :- 80°C - Pressure :- 6
Bar - Diameter : - Ψ 12mm
Sensing Electrode :- Platinum - Diaphragm :- Open
Hole - Electrolyte :- KCL Gel - Length :- 122mm
Applications
| Cooling Towers | Ozone Systems | Galvanic
Processes | Swimming Pools | Wastewater |
Redox Electrode
Type RX4-HT-DJ
Key Features
Specially formulated glass body
for operations up to 130°C temperature the ideal choice for volatile industrial cycles
Exceptional measurement
precision unaffected by flow or temperature fluctuation ensures long term process stability
Detachable S8 cable connection with screwed PG13.5 configuration to head of electrode with BNC type connector
Technical Details
Measurement :- ± 2000 mV - Temperature :- 130°C (6 Bar) - Pressure
:- 16 Bar (25°C)
Sensing Electrode :- Platinum - Diaphragm :- Triple Open Hole
- Electrolyte :- KCL Gel
Mechanical Connection :- PG 13.5mm - Shaft Diameter :
- Ψ 12mm - Length :- 122mm
Applications
| Ammonia | Chrome Plating | Reverse
Osmosis | Galvanic Processes | Bisulfite Applications |
Electronic Dosing Systems
Tel 01299 825 656 Email info@electronicdosingsystems.co.uk
Solutions For All Metering & Measurement Processes
Copyright: - Electronic Dosing Systems 2026
| Water Treatment | Electroplating | Cooling Towers | Industrial Boilers | Beverage & Breweries | Vehicle
Washing | Waste Water Treatment | Swimming Pools & Spas |
| Paper Industry | Petroleum | Bottle Washing |
Hygiene & Cleaning | Biotechnology | Food Industry | Pharmaceutical Industry |
Redox (orp) Probe
Platinum Sensing System
High-performance single junction Redox (ORP) Probe with robust platinum
sensing element and a high-quality silver/silver chloride (Ag/AgCl) high performance reference system that excels in applications
ranging from general laboratory use, swimming pools to industrial wastewater treatment processes, sensor measures Oxygen
Reduction Potential in aqueous solutions with clinical precision its streamlined single-junction design ensures fast response
times making it the ideal tool for spotting rapid chemical shifts.
Redox (orp) Probe
Gold Reference System
This high-performance ORP probe features single junction gold sensing
reference system engineered specifically for high-demand industrial water treatment applications offering unparalleled resistance
to oxidation and chemical poisoning capturing fluctuations of Oxygen Reduction Potential in real-time with minimal
lag, the specialised reference system maintains clinical accuracy in cyanide destruction, ozone monitoring, and high-chlorine
process environments without the need for constant recalibration of the sensor.
Redox (orp) Sensor
Platinum Reference System
Designed for challenging environments in critical processes Double
Junction Redox (ORP) Sensor features a high-purity robust platinum reference electrode housed in a polycarbonate body ensures
rapid response times and unparalleled stability in volatile solutions, the double junction design acts as a fortified barrier
preventing reference contamination and "poisoning" from aggressive chemicals significantly extending the sensors lifespan to deliver
the precision required in managing critical process control applications.
Redox (orp) Sensor
Temperature 80° Operation
Encased in a reinforced grass body this Double Junction ORP Sensor with
high-purity platinum sensing electrode engineered for precision and longevity in demanding environments its dual-junction design
provides a superior barrier against contamination significantly extending sensor life in samples containing sulfides or heavy metals,
designed for resilience it operates seamlessly at 80°C temperatures delivering stable readings and rapid response times with
exceptional sensitivity for all your oxidation-reduction potential measurements.
Redox (orp) Sensor
Temperature 130° Operation
High precision durable Double Junction ORP Sensor housed in heat
resistant glass body engineered for superior response times due to it's high-purity robust platinum reference
sensor and double junction system to prevent contamination whilst significantly extending the sensors lifespan, designed
to withstand harsh its resilience to operate seamlessly in working conditions at 130°C temperatures delivering stable
readings and rapid response times with exceptional sensitivity for all your oxidation-reduction potential measurements.
Associated Control Equipment